    Single Hospital Pager 50 - 60hz Rated Input Frequency 100 - 240 Vac

    Ask Lasest Price
    Brand Name : WEX
    Model Number : W8008C
    Certification : CE,FCC,ROHS
    Price : Negotiable
    • Product Details
    • Company Profile

    Single Hospital Pager 50 - 60hz Rated Input Frequency 100 - 240 Vac

    Charging operation and Description: plug the power adapter into AC power socket (as shown), Install the charging W8008 pager in the direction shown in the charging seat, Red LED indicator light at the upper right corner is on , Suggesting it is charging. Normal charge is about 3 hours. When the power is full, the top right corner of the pager will turn on the green LED light, Chargingcompletes since then


    Adapter technology specifications:

    Input Characteristics:

    Rated input voltage100-240Vac
    Operating range90-264Vac
    Rated input frequency50-60Hz
    Rated input current0.3A Max.

    Power consumption (no loading)

    Power consumption (no loading)


    0.3W Max.(Input voltage 115V and 230V)

    Under the 115V and 230V input voltage conditions, 0.3W ,Max

    Primary current protection

    An adequate internal fuse on the AC input line is provideed.


    ConfigurationConductor power

    Output Characteristics:

    2.2.1

    Nominal dc output voltage


    5.0V

    Minimum load current


    0.01A
    2.2.3

    Rating load current


    1.0A

    Rating output power


    5.0W
    2.2.5

    Line regulation


    The line regulation is less than ±5% while measuring at rated load and +/-10% of input voltage changing.


    Load regulation


    The load regulation for +5.0V is less than ±5%, at measured output load from 10% to 100% rated load .


    2.2.7

    No load voltage range


    4.75~5.30V
    2.2.8

    Ripple and noise


    100mVp-p

    Full load Ripple and noise 100mVp-pmax.

    Measurement is done by 20MHZ bandwidth oscilloscope and the output Paralleled a 0.1μF ceramic capacitor and a 10μF electrolysis capacitor.(test under the Condition of rated input and rated output)

    2.2.9

    Average efficiency


    Accord with energy level V. Average efficiency68.17% minimum



    115V/60Hz and 230V/50Hz, output current from 100%, 75%, 50%, 25%.